For Hazardous Zone Pressure and Flow Applications
Intrinsically Safe Differential Pressure Transmitter can be programmed to read in pressure, flow, or velocity in hazardous locations.
 
Features
	- 
	NEMA 4X rated enclosure provides protection in harsh environments permitting outdoor monitoring or in areas where dust and particulate matter exists 
- 
	Easy to read LCD display provides immediate local alerts allowing corrective action to be taken quicker to eliminate the problem from becoming widespread 
- 
	Intrinsically safe for use in the specified hazardous locations meets specifications where pressure transmission and safety cannot be compromised 
- 
	Password protected set up menu helps to insure no errors by untrained personnel when accessing the powerful measurement capabilities of this device 
Product Applications
Specifications
	- 
	Service: Air and non-combustible gases. 
- 
	Wetted Materials: Ranges 5 in w.c. and Greater: glass, PVC, silicon, alumina ceramic, epoxy, RTV, gold, aluminum, stainless steel and nickel; Ranges 1 in w.c. and Lower: stainless steel, silicone, gold, ceramic. 
- 
	Housing Materials: Aluminum, glass. 
- 
	Accuracy: ±0.5% at 77°F (25°C) including hysteresis and repeatability (after 1 hour warm-up). 
- 
	Stability: < ±1% per year. 
- 
	Pressure Limits: Ranges ≤ 2.5 in w.c.: 2 psi; 5 in w.c.: 5 psi; 10 in w.c.: 5 psi; 25 in w.c.: 5 psi; 50 in w.c.: 5 psi; 100 in w.c.: 9 psi. 
- 
	Temperature Limits: 32 to 140°F (0 to 60°C). 
- 
	Compensated Temperature Limits: 32 to 140°F (0 to 60°C). 
- 
	Thermal Effects: 0.020%/°F (0.036/°C) from 77°F (25°C). 
- 
	Power Requirements: 10 to 35 VDC. 
- 
	Output Signal: 4 to 20 mA DC. 
- 
	Zero & Span Adjustments: Accessible via menus. 
- 
	Response Time: 250 ms (damping set to 1). 
- 
	Display: 4 digit LCD 0.6" height. 
- 
	Electrical Connections: M-12 4 PIN Connector. 
- 
	Process Connections: 1/8" female NPT. 
- 
	Enclosure Rating: Designed to meet NEMA 4X (IP66). 
- 
	Mounting Orientation: Mount unit in vertical plane. 
- 
	Weight: 2 lb 10 oz (1.19 kg). 
- 
	Agency Approvals: CE: CENELEC EN 61326/55024: 2003; IEC 61000-4-2/3/4/6: 2001/2006/2004/2005; CENELEC EN 55011: 2006; 2004/108/EC EMC Directive; FM Intrinsically Safe CLI Div I GR: A, B, C, D; CLII Div I GR: E, F, G; CLIII Div I.