Thông số kỹ thuật:
- Service: Compatible solids and liquids.
- Wetted Materials: PVDF.
- Range: Liquids: 26.25' (8 m); Solids: 19.69' (6 m).
- Accuracy: ±0.5 cm (±0.2?) or 0.2% of max. range.
- Repeatability: 0.2% of measured range.
- Resolution: 0.04" (1 mm).
- Blind Zone: 5.91" (15 cm).
- Beam Angle: 5° @ 3 db point.
- Temperature Limits: -4 to 158°F (-20 to 70°C).
- Temperature Compensation: Automatic.
- Power Requirements: 8 to 33 VDC.
- Current Consumption: Continuous: 10 mA @ 24 VDC; SMS Transmission: 40 mA @ 24 VDC; Switch Output: 160 mA @ 24 VDC.
- Process Tracking Rate (max.): 0.55 ft/s (10 m/min).
- Electrical Connections: Screw terminal.
- Conduit Connections:: 1/2" female NPT.
- Process Connections: 1-1/2" male NPT, 1-1/2" BSP optional.
- Enclosure Material: Plastic PC/ABS+UV.
- Enclosure Rating: IP65/IP67, IP68 (96 hours at 5.91' (1.8 m) water depth).
- Mounting Orientation: Vertical.
- Memory: Non-volatile.
- Display: 64 x 128 graphic LCD.
- Units: m, m/min, °F or °C (selectable).
- Programming: 4-button.
- Weight: 1.95 lb (884.51 g).
***ULTM only supports one accessory at a time. External battery not included.
CELLULAR MODEM
- Band: Quad band 850/900/1800/1900 mHz.
- Output Power: Class 4 (33 dBm) for EGSM850/EGSM900; Class 1 (30 dBm) for GSM180/GSM1900.
- SMS: Point-to-point MO and MT.
- GPRS: Multi-slot class 10.
- Reports Display: Level, volume, temperature.
- SMS Resolution: 0.04" (1 mm).
- Report Type: Empty, full, theft alert, refilling alert and periodic report.
- Accuracy: 0.5 to 2' (0.15 to 0.6 m): ±0.6" (±1.5 mm); 2 to 16.5' (0.6 to 5 m): ±0.3% of measured range; 16.5 to 26.25' (5 to 8 m): ±0.2% of max. range.
Ordering:
Model
|
Description
|
ULTM-00
|
Ultrasonic level transmitter, mobile.
Note: The ULTM only supports one accessory at a time.
|